Guides & Manuals

Complete Owner's Guide

Wiring Diagram

Product Specifications Sheet

Propietario completa Guía

Guide d'utilisation complet


  • What is the proper way to clean my air filter?

    The air filter should be checked at least once a month to see if cleaning is necessary. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. To clean the filter, open the front panel and remove. The air filter is reusable and may be cleaned using liquid dishwashing detergent and warm water. After cleaning allow the filter to thoroughly dry before replacing. You may also vacuum the air filter to remove excess dirt and particles.

  • Can my room air conditioner be covered while in use to prevent outdoor debris from getting inside vents?

    Proper air flow into the air conditioner is essential for performance and safe operation. Under no circumstances should you block or cover any exterior or interior vents of the unit.

  • How does the power cord work on my air conditioner? When should I test the plug?

    For your safety all Frigidaire air conditioners feature a 3-prong grounding plug and current leakage detection device. These enhanced plugs help to detect damages to the power cord and can be tested following a few simple steps. 1. Press the reset button 2. Plug the cord into the power outlet 3. Press the test button, the reset button should pop up 4. Press reset button for use 5. Do not use room air conditioner if above test fails. For more information please consult your use and care manual.

  • What is the additional vent located under my air louvers?

    On select models, you may notice a small tab identified with Open / Fresh Air / Closed.

    This fresh air vent allows the air conditioner to: 1. Recirculate inside air - Vent Closed 2.  Draw fresh air into the room - Fresh Air  3.  Expel indoor air outside - Vent Open. Note: When in the cool mode fresh air venting or exhaust venting will affect cooling and decrease performance.

  • I have noticed water dripping outside of my room air conditioner, is this normal?

    Water dripping outside is a normal function of the room air conditioner, especially during periods of excessive humidity. If condensation need to be directed, window air conditioners have a key hole drain in the bottom of the unit where one could connect a ½” drain hose for safe disposal of excess system water.  Part: EA150D / 5304481680. Never drill holes into the bottom of the room air conditioner to remove water. If water is dripping inside the room during the cooling, this is due to improper installation. Please refer to installation instructions or check with your local installer.

  • I have noticed that my ENERGY STAR air conditioner is frequently in Econ mode?

    For all new ENERGY STAR products the EPA has regulated that all ENERGY STAR air conditioners must be factory set to Energy Saver (Econ) mode. If you turn the room air conditioner off in cool mode, and restart the unit it will default back into Energy Saver mode. You may select out of Energy Saver mode by selecting the mode button, however we recommend using the feature to help save energy. 

  • What is Econ mode?

    Econ mode, or Energy Saver mode, is a setting that works similar to central AC. The room air conditioner will turn off once the set temp is reached; the fan then cycles on (for 20 sec.) every 10 min to sample the air temp. If the room temp is above the set temp, the compressor will turn back on. Since the room air conditioner is not running at all times, this setting will help save energy while ensuring the room temperature stays at the set temperature.

  • What does the Clean Air button do?

    When this feature is on, the electronic air purifier is energized to remove pollen and impurities from the air. To cancel this feature, press the Clean Air button. 

  • What is a BTU?

    It is a professional term rating an air conditioner. BTU stands for British Thermal Unit - the quantity of heat required to raise the temperature of one pound of water one degrees Fahrenheit. The higher the BTU the larger space the room air conditioner will cool.

  • What size window unit do I need?

    The size of the window unit needed will depend on the size of the room you wish to cool. To determine which size you need, measure the width of the room by the length and multiply those numbers together to determine the square footage.  



  • What happens if I lose power?

    After a power outage, the unit will memorize the last setting and return the unit to the same setting once power is restored.  

  • What does Sleep Mode mean?

    When this mode is enabled, the selected temperature will increase by 2 °F 30 minutes after the mode is selected.  The temperature will then increase by another 2 °F after an additional 30 minutes.  This new temperature will be maintained for 7 hours before returning to the originally selected temperature.  This ends the “Sleep” mode and the unit will continue to operate as originally programmed.  You may also cancel sleep mode at any time by again pressing the sleep button.

  • Why is my room air conditioner making noise?

    Room Air Conditioners, during operation, may make noise.  It is normal to hear ‘high pitch chatter’ a sound of rushing air, gurgle/hiss, pinging or swishing and vibration.  These are all normal.  For more definition of noises, please refer to your product’s Use and Care guide.

  • How do I store my room air conditioner for winter storage?

    If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions.  Cover it with plastic or return it to its original carton.  NOTE:   To prevent rust or electrical connections from being damaged, store air conditioner in an upright position and a dry place.

  • Why is my Filter Reset light on?

    This feature is a reminder to clean the Air Filter (refer to Care and Cleaning section of the Use and Care Guide) for more efficient operation.  The LED light will illuminate after 250 hours of operation. After cleaning the filter, plug the unit back into the power source and reset the filter by pressing the ‘Filter Reset’ button and the light will go off.


Effortless™ Temperature Control

Frigidaire® air conditioners maintain the preset room temperature so the room remains comfortable at all times, while controling energy usage.

Effortless™ Restart

In the event of a power outage, self-enabling Effortless™ restart feature automatically resumes operating at previous settings when power is restored.

Effortless™ Operation

Simple, intuitive room controls are easy for guests to operate — ensuring a relaxing, more comfortable stay. Features like Effortless™ Auto Restart and Ready-Select® LCD controls reduce maintenance calls.

Energy Saver Mode

Energy Saver Mode can help reduce your utility bills, while still keeping guests cool, by maximizing energy efficiency. In this mode, the unit doesn't run at all times, it turns on and off at different intervals to ensure that the room temperature stays at the set temperature.


Sound reduction package.

Multi-Speed Fan

Offers your guests more cooling flexibility with three adjustable fan settings as well as cool, heat and fan-only options.

Effortless™ Control

Frigidaire® PTACs are designed to make guest's time away from home even easier. By adding an optional remote thermostat, you can allow guests to effortlessly control their temperature and air movement from anywhere in the room.


Frigidaire® uses R-410A refrigerant that’s not harmful to the earth’s ozone layer and meets U.S. Environmental Protection Agency requirements.

Effortless™ Maintenance

With Frigidaire®’s reputation for durability, easy maintenance, availability of reliable parts, and service you can count on, you can be sure that you’re getting the highest-quality performance.

Effortless™ Protection

Corrosion-resistant fin coating extends operation life and your investment, plus it is easier to maintain in coastal environments.

Effortless™ Clean Air Filter

The upfront location of the filter makes regular cleaning quick and effortless, prolonging the life of the unit.

Effortless™ Auto Freeze Protection

Unit operates at a low voltage to protect unoccupied rooms from freezing temperatures.

Ready-Select® Electronic Controls

Simply select options with the touch of a button.

Smart Self-Check

Provides nine diagnostic points for self-check and correction of fault conditions.

Effortless™ Random Restart Protection

Delays restart after a power outage to protect the electrical circuit from power surges.


General Specifications

  • Refrigerant: R410a
  • Max Wall Thickness: 13-13/16"
  • Warranty: 2 Year Full/5 Year Sealed System
  • Shipping Weight (lbs): 135
  • Product Weight (lbs): 111
  • ProductLaunch: NA
  • Stack Height: 6
  • Stuff Quantity: 180
  • Power Type: None
  • Size: N/A
  • Installation Type: Built-In
  • Collection: Frigidaire


  • Control Location: Top Right
  • Controls: Electronic


  • Carton Height: 18-1/8"
  • Carton Width: 44-7/8"
  • Carton Depth: 25-5/16"


  • Air Intake: Fresh or Recycled Air
  • Slide-Out Chassis: Yes
  • Fan Auto: Yes
  • Filter Access - Frig: Slide-Out
  • Low Voltage Start-up: Yes
  • Motor RPM (High/Med/Low): 1100/1000/920
  • Quiet Start-Up: Yes
  • Random Restart Protection: Yes
  • Front Desk Control Ready: Yes
  • Cabinet Louvers: No
  • Fan Speeds - Cool/Fan/Heat: 2003-03-03
  • 24-Hour On/Off Timer: Yes

Certifications & Approvals

  • Safety Certification: UL/CUL/CSA

Exterior Dimensions

  • Case Width: 42"

AC Specifications

  • Air Direction Control: Auxiliary 2-Way
  • Air Volume (CFM) (Max./Med./Min.): 315/295/275
  • Charge (ozs): 26.8
  • Energy Saver: Yes
  • Filter Type: PA/Nylon Mesh
  • Fin Coating: Seacoast
  • Noise Level dB (High/Med/Low): 53/52/51
  • Room Freeze Protection: Yes

Electrical Specifications

  • Amps (Electrical Heat): 13.2 / 12.2
  • Amps (Heat Pump): 4.5 / 4.7
  • Amps (Cool): 5.1 / 5.3
  • Circuit Breaker: 20A
  • Cable Included: Yes
  • Horsepower (Cool): 1.5
  • Voltage Rating: 230V / 208V 60Hz
  • Watts (Cool): 1120 / 1120
  • Watts (ElectricalHeat): 3000 / 2452
  • Watts (Heat Pump): 1010 / 990
  • Power Cord Length: 5-1/2'
  • Plug Type: LCDI 6-20P

Dimensions: Cut-Out

  • Width (Min): 42-3/16"
  • Height (Min): 16-5/16"


  • Performance Certification: AHRI & CEC
  • BTU (Cool): 12000 / 11800
  • Cool Area (Sq. Ft.): 640
  • Dehumidification (Pints/Hour): 2.7
  • Energy Efficiency Ratio: 10.7 / 10.5
  • BTU (Electrical Heat): 10200 / 8300
  • BTU (Heat Pump): 10700 / 10500
  • COP (Heat Pump): 3.1/3.1

Dimensions: Exterior

  • Height: 16"
  • Width: 42"
  • Depth: 13-13/16"
  • Cabinet Depth: 13-13/16"
  • Cabinet Height: 16"


This product has been successfully added to your cart! « Go back to product page